SCSI-III External Hi D-Sub (Single-ended)
From HwB
Pinout
68 PIN HI-DENSITY D-SUB FEMALE at the controller & devices.
68 PIN HI-DENSITY D-SUB MALE at the cable.
| Pin | Name | Dir | Description |
|---|---|---|---|
| 1-16 | GND | |
Ground |
| 17 | TERMPWR | |
Termination Power |
| 18 | TERMPWR | |
Termination Power |
| 19 | res | |
reserved |
| 20-34 | GND | |
Ground |
| 35 | DB12 | |
Data Bus 12 |
| 36 | DB13 | |
Data Bus 13 |
| 37 | DB14 | |
Data Bus 14 |
| 38 | DB15 | |
Data Bus 15 |
| 39 | DPB1 | |
Data Parity (odd Parity) |
| 40 | DB0 | |
Data Bus 0 |
| 41 | DB1 | |
Data Bus 1 |
| 42 | DB2 | |
Data Bus 2 |
| 43 | DB3 | |
Data Bus 3 |
| 44 | DB4 | |
Data Bus 4 |
| 45 | DB5 | |
Data Bus 5 |
| 46 | DB6 | |
Data Bus 6 |
| 47 | DB7 | |
Data Bus 7 |
| 48 | DPB | |
Data Parity (odd Parity) |
| 49 | GND | |
Ground |
| 50 | GND | |
Ground |
| 51 | TERMPWR | |
Termination Power |
| 52 | TERMPWR | |
Termination Power |
| 53 | res | |
reserved |
| 54 | GND | |
Ground |
| 55 | /ATN | |
Attention |
| 56 | GND | |
Ground |
| 57 | /BSY | |
Busy |
| 58 | /ACK | |
Acknowledge |
| 59 | /RST | |
Reset |
| 60 | /MSG | |
Message |
| 61 | /SEL | |
Select |
| 62 | /C/D | |
Control/Data |
| 63 | /REQ | |
Request |
| 64 | /I/O | |
Input/Output |
| 65 | DB8 | |
Data Bus 8 |
| 66 | DB9 | |
Data Bus 9 |
| 67 | DB10 | |
Data Bus 10 |
| 68 | DB11 | |
Data Bus 11 |
Note: Direction is Device relative Bus (other Devices).